In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX

OBJECTIVES To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. MATERIAL AND METHODS Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex ...

متن کامل

Radiographic versus electronic root canal working length determination.

PURPOSE The aim of this ex vivo study was to compare the accuracy of radiographic and electronic root canal length determination methods, compared with actual root canal length obtained with stereomicroscope. MATERIALS AND METHODS Thirty extracted single-rooted permanent teeth were used for this study. After access preparation, actual length (AL) of the root canal were determined for each too...

متن کامل

Comparison of the accuracy of conventional and digital radiography in root canal working length determination: An invitro study

Background. Digital radiography has widespread use in endodontics. Determining a correct working length is vital for a proper endodontic therapy. The aim of this study was to compare the accuracy of conventional and digital radiographic techniques for root canal working length determination. Methods. After determining the real working lengths of 50 permanent maxillary central incisors (gold sta...

متن کامل

Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study.

INTRODUCTION This ex vivo study evaluated the accuracy of the Root-ZX electronic apex locator (EAL) (J. Morita, Tokyo, Japan) and the NovApex (Forum Technologies, Rishon Lezion, Israel) in determining the working length (WL) during endodontic treatment. MATERIALS AND METHODS Forty extracted single-rooted human teeth were selected for this study. The actual WL was measured with visual techniqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Oral Science

سال: 2012

ISSN: 1678-7757

DOI: 10.1590/s1678-77572012000500005