In vitro chemotaxis and tissue remodeling assays quantitatively characterize foreign body reaction

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro chemotaxis and tissue remodeling assays quantitatively characterize foreign body reaction.

Surgical implantation of a biomaterial triggers foreign-body-induced fibrous encapsulation. Two major mechanisms of this complex physiological process are (I) chemotaxis of fibroblasts from surrounding tissue to the implant region, followed by (II) tissue remodeling. As an alternative to animal studies, we here propose a process-aligned in vitro test platform to investigate the material depende...

متن کامل

Tissue remodeling investigation in varicose veins

Although the etiology of varicose veins remains unknown, recent studies have focused on endothelial cell integrity and function because the endothelium regulates vessel tone and synthesizes many pro- and anti-inflammatory factors. The aim of this study was to investigate the evidence involving the endothelium in the development of varicose vein disease. In addition, tissue remodeling was invest...

متن کامل

Polycaprolactone nanofibrous mesh reduces foreign body reaction and induces adipose flap expansion in tissue engineering chamber

Tissue engineering chamber technique can be used to generate engineered adipose tissue, showing the potential for the reconstruction of soft tissue defects. However, the consequent foreign body reaction induced by the exogenous chamber implantation causes thick capsule formation on the surface of the adipose flap following capsule contracture, which may limit the internal tissue expansion. The ...

متن کامل

Sarcoidal Type Foreign Body Reaction: A Case Report

Sarcoidosis and foreign body reactions are common differential diagnoses of skin granuloma formation. We report a 40 year –old man with sarcoid type granulomas containing polarized foreign materials, and also bilateral hilar adenopathy. It appears that detection of foreign bodies in histopatologic studies of granulomas does not necessarily exclude the possibility of sarcoidosis.

متن کامل

Invasive Intraneural Interfaces: Foreign Body Reaction Issues

Intraneural interfaces are stimulation/registration devices designed to couple the peripheral nervous system (PNS) with the environment. Over the last years, their use has increased in a wide range of applications, such as the control of a new generation of neural-interfaced prostheses. At present, the success of this technology is limited by an electrical impedance increase, due to an inflamma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ALTEX

سال: 2017

ISSN: 1868-596X

DOI: 10.14573/altex.1610071