IMRT and RapidArc commissioning of a TrueBeam linear accelerator using TG-119 protocol cases
نویسندگان
چکیده
منابع مشابه
IMRT and RapidArc commissioning of a TrueBeam linear accelerator using TG‐119 protocol cases
The purpose of this study is to evaluate the overall accuracy of intensity-modulated radiation therapy (IMRT) and RapidArc delivery using both flattening filter (FF) and flattening filter-free (FFF) modalities based on test cases developed by AAPM Task Group 119. Institutional confidence limits (CLs) were established as the baseline for patient specific treatment plan quality assurance (QA). Th...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملEstimation of local confidence limit for 6 MV photon beam IMRT system using AAPM TG 119 test protocol
1Department of Radiation Oncology, SevenHills Hospital, Mumbai, India 2Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, India Received October 17, 2015; Revised January 02, 2016; Accepted January 16, 2016; Published Online February 03, 2016 Original Article Abstract Purpose: The aim of this study was to estimate local confidence limit for 6 MV photon beam based...
متن کاملCommissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کاملCommissioning and acceptance testing of a CyberKnife linear accelerator
Acceptance testing and commissioning of a CyberKnife robotic stereotactic radiosurgery system was performed in April 2006. The CyberKnife linear accelerator produces a photon beam of 6 MV nominal energy, without the use of a flattening filter. Clinically measured tissue-phantom ratios, off-center ratios, and output factors are presented and compared with similar data from other CyberKnife sites...