Improving the low voltage ride through of doubly fed induction generator during intermittent voltage source converter faults

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

متن کامل

Low voltage ride-through strategies for doubly fed induction machine pumped storage system under grid faults

Pumped storage units bring stability to the electrical power system, so they must remain connected to the grid even during grid faults. In this paper, the authors propose efficient and simple solutions for a doubly fed induction machine pumped storage (DFIMPS) system during grid faults. In case of balanced grid faults, a control reconfiguration strategy is introduced and a hardware solution is ...

متن کامل

Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement

A novel control strategy is proposed in this paper for the rotor side converter (RSC) of doubly-fed induction generator (DFIG)-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT) capability of DFIGs during great-level grid voltage dips. The strategy consists of a proportional-resonant (PR) controller and auxiliary PR controllers. The auxiliary cont...

متن کامل

A New Method to Enhance the Low Voltage Ride Through Capability of Doubly Fed Induction Generator Using Resistive Type Superconducting Fault Current Limiter

In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...

متن کامل

High Voltage Ride Through with FACTS for Wind Turbines with Doubly Fed Induction Generator

In future grid codes wind farms will have to fulfill demanding fault ride through requirements. Among several grid faults the voltage swell is a critical event. Wind farms with doubly-fed induction generators will not be able to fulfill the new grid code requirements without additional fault mitigation equipment. In this publication the applicability of the Dynamic Voltage Restorer and the Stat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Renewable and Sustainable Energy

سال: 2013

ISSN: 1941-7012

DOI: 10.1063/1.4812651