Improvements in micro-CT method for characterizing X-ray monocapillary optics

نویسندگان

چکیده

Accurate characterization of the inner surface X-ray monocapillary optics (XMCO) is great significance in research. Compared with other methods, micro computed tomography (micro-CT) method has its unique advantages but also some disadvantages, such as a long scanning time, image reconstruction and inconvenient process. In this paper, sparse sampling was proposed to shorten GPU acceleration technology used improve speed reconstruction, simple geometric calibration algorithm avoid phantom simplify These methodologies will popularize use micro-CT XMCO characterization.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monocapillary Optics Developments and Applications

Hollow glass tubes are in use at Cornell High Energy Synchrotron Source (CHESS) as X-ray optics in the 4 to 25 keV range to take large diameter, fairly parallel X-ray beams and compress them into smaller diameter, more divergent beams for various kinds of X-ray applications. The optics come in two forms: 1) multibounce condensing capillaries for making submicron diameter beams and 2) one-bounce...

متن کامل

Single-element elliptical hard x-ray micro-optics.

Using micro-fabrication techniques, we have manufactured a single element kinoform lens in single-crystal silicon with an elliptical profile for 12.398 keV (1A) x-rays. By fabricating a lens that is optimized at fixed wavelengths, absorption in the lens material can be significantly reduced by removing 2_ phase-shifting regions. This permits short focal length devices to be fabricated with smal...

متن کامل

An X-ray polarimeter for hard X-ray optics

Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer ...

متن کامل

X-ray micro-CT with a displaced detector array.

Because the sizes of samples differ in x-ray micro-CT applications, it is desirable to have a mechanism to change the field of view of a micro-CT scanner. A well-known way to double the diameter of the field of view is to displace a detector array by 50%. In this paper, we propose to displace a detector array by an amount of greater than 0% but less than 50% for a continuously adjustable field ...

متن کامل

A single-image method for x-ray refractive index CT.

X-ray refraction-based computer tomography imaging is a well-established method for nondestructive investigations of various objects. In order to perform the 3D reconstruction of the index of refraction, two or more raw computed tomography phase-contrast images are usually acquired and combined to retrieve the refraction map (i.e. differential phase) signal within the sample. We suggest an appr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Communications

سال: 2022

ISSN: ['1873-0310', '0030-4018']

DOI: https://doi.org/10.1016/j.optcom.2021.127474