Improvement Vortex Cooling Capacity by Reducing Hot Tube Surface Temperature: Experiment
نویسندگان
چکیده
منابع مشابه
Investigate of Manuel Cooling System Used Vortex Tube
In this study, a functional vest which can be worked by manuel without any starting system was designed and a prototype was produced for peoples cooling requirement. This system was made of a vortex tube, knee pad, linear motion mechanism with 3 members and vest. While walking, depending on knee’s movement, a piston at linear motion mechanism was moved front and backward. This front and back mo...
متن کاملAn Improvement on Land Surface Temperature Determination by Producing Surface Emissivity Maps
Emissivity mapping of the Earth’s surface is the prerequisite to thermal remote sensing. A precise determinationof a surface's temperature is dependent upon the availability of precise emissivity data for that surface. The presentstudy area is a part of sugarcane plantation fields in the west part of Khuzestan province. In this work, TemperatureEmissivity Separation algorithm (TES) was applied ...
متن کاملHigh temperature exposure increases plant cooling capacity
the narrow sense. While the concept of qualia is elusive, its neurobiological basis can be investigated with the empirical neuroscientific approach. For example, with a rewiring experiment such as the one described above we may be able to uncover patterns of neuronal connectivity that are associated with visual and auditory qualia. Once anatomical motifs are identified for typical visual and au...
متن کاملA new approach to selective brain cooling by a Ranque-Hilsch vortex tube
BACKGROUND Target temperature management is the single most effective intervention and the gold standard in post-resuscitation care today. However, cooling the whole body below 33-34 °C can cause severe complications. Therefore, developing a selective brain cooling (SBC) approach which can be initiated early to induce rapid cooling and maintain the target temperature over 12-24 h before slowly ...
متن کاملIncreasing Cooling Towers Heat Capacity by Flue Gas Introduction
In this paper the changes in the heat capacity of cooling towers has been investigated as a result of injecting combustion products of boilers. In the tower, the air is re-heated through mixing with hot flue gas after passing through the heat exchangers. As a result of this process, the draft of the cooling tower is increased. The additional produced draft depends on the ambient temperature and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy Procedia
سال: 2014
ISSN: 1876-6102