Improvement of thermal performance of the finned tube flat plate solar water heater
نویسندگان
چکیده
منابع مشابه
Thermal Performance of a Double-pass Solar Air Heater
This study analyzes the thermal performance of solar thermal energy using double-pass absorber plate in Sanandaj, Iran. To this end, a mathematical model was encoded according to the energy and exergy balance equations and solved by MATLAB software. Given the environmental conditions and radiation intensity of a winter day in Sanandaj, the effects of external parameters such as radiation intens...
متن کاملThermal and economic analysis of low-cost modified flat-plate solar water heater with parallel two-side serpentine flow
The present study deals with the thermal performance evaluation and economic analysis of a low-cost modified flat-plate solar water heater (SWH) with a parallel two-side serpentine flow. This is a unique inexpensive and easily fabricated SWH having better thermal efficiency than those investigated by earlier authors. The solar water heating system is having parallel two-side serpentine arrangem...
متن کاملthe role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
Investigating the effect of hot water consumption profile on the performance of solar water heating systems
In this paper, a forced circulation solar water heater system is simulated for different hot water consumption profiles using flat plate collectors as well as evacuated tube collectors. The profiles studied are the actual samples of hot water consumption profiles for different commercial centers and institutions. Dynamic simulation outputs of system thermal performance are used as economic anal...
متن کاملThe Effects of Frost Formation in a Flat Plate Finned-Tube Heat Exchanger
An experimental study on the effects of various factors(fin spacing, fin arrangement, air temperature, air humidity, and air velocity) on the frost growth and thermal performance of a finned-tube heat exchanger has been conducted under the frosting condition. It is found that the thermal performance of a heat exchanger is closely related to the blockage ratio of air flow passage due to the fros...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Earth and Environmental Science
سال: 2021
ISSN: 1755-1307,1755-1315
DOI: 10.1088/1755-1315/753/1/012014