Improvement of Nonuniformity on Flatbed Scanner for Radiochromic Film Dosimetry Using Average Correction Factor with Multi-direction Scan Data

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry

The purpose of this study was to quantify the performance and assess the utility of two different types of scanners for radiochromic EBT film dosimetry: a commercial flatbed document scanner and a widely used radiographic film scanner. We evaluated the Epson Perfection V700 Photo flatbed scanner and the Vidar VXR Dosimetry Pro Advantage scanner as measurement devices for radiochromic EBT film. ...

متن کامل

Reference dosimetry using radiochromic film

The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparin...

متن کامل

Evaluation of a single‐scan protocol for radiochromic film dosimetry

The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calib...

متن کامل

Radiochromic Film Dosimetry

Published by the American Association of Physicists in Medicine DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as...

متن کامل

Dosimetry of blood irradiation with radiochromic film.

It has been shown that radiochromic film is an ideal dosimeter for assessment and verification of delivered dose to irradiated blood products. Using a parallel opposing two-field technique on a medical linear accelerator, blood is irradiated to diminish the risk of transfusion-associated graft vs. host disease (TA-GVHD). The blood products are irradiated in a Perspex blood box to an applied dos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 2020

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.2020_jsrt_76.4.375