Improvement of DC Fault Current Limiting and Interrupting Operation of Hybrid DC Circuit Breaker Using Double Quench
نویسندگان
چکیده
In this paper, direct current (DC) fault limiting and interrupting operation of hybrid DC circuit breaker (DCCB) using double quench, which consists DCCB, a series resonance circuit, power electronic switch, surge arrestor, two separated reactor/resistor, superconducting elements, were suggested. The suggested DCCB can perform the after twice or once according to amplitude. To verify effective modeling for components SCE was carried out its operational characteristics analyzed. Through analysis results advantages discussed.
منابع مشابه
A New Circuit Topology for Open Circuit and Short Circuit Fault Tolerant Dc - Dc Converter
This paper describes a new design for a fault tolerant Hbridge dc-dc converter. Open circuit and short circuit fault tolerance is achieved using multilevel converter topology in combination with pulse width modulation control strategy allowing a large set of converter switching states to produce bidirectional power flows at any required output voltage. If two switches fail at particular instant...
متن کاملA Developed Structure of Step-Up DC/DC Converter by Using Coupled Inductor and Active Clamped Circuit
In this paper, a new structure of step-up dc-dc converter by using coupled inductor and active-clamped circuit is proposed. The proposed converter generates high voltage gain in comparison with the conventional dc-dc converters. Duo to using active-clamped circuit in the proposed topology the voltage stress on main switch is reduced. In addition the zero voltage switching (ZVS) in ON-state of m...
متن کاملMppt Controlled Dc-Dc Converter Using Passive Absorption Circuit
This paper introduces the use of the voltage multiplier technique and passive absorption circuit applied to the non-isolated dc-dc converter in order to obtain high efficiency and high voltage gain. A passive absorption circuit is inserted in the interleaved flyback converter to transfer the leakage energy to load. The operation principle of the circuit is explained. This paper also deals with ...
متن کاملDC Fault Ride-through Capability and STATCOM Operation of a HVDC Hybrid Voltage Source Converter
HVDC transmission systems are becoming increasingly popular when compared to conventional AC transmission methods. HVDC voltage source converters (VSC) can offer advantages over traditional HVDC current source converter topologies; as such, it is expected that HVDC-VSCs will be further exploited with the growth of HVDC transmission. This paper presents the DC fault ride through capability and n...
متن کاملFault Detection and Classification in Double-Circuit Transmission Line in Presence of TCSC Using Hybrid Intelligent Method
In this paper, an effective method for fault detection and classification in a double-circuit transmission line compensated with TCSC is proposed. The mutual coupling of parallel transmission lines and presence of TCSC affect the frequency content of the input signal of a distance relay and hence fault detection and fault classification face some challenges. One of the most effective methods fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2021
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en14144157