Improvement of Brain Contrast Using Spin Echo T<sub>1</sub>-weighted Image at 3 T MRI
نویسندگان
چکیده
منابع مشابه
comparison of maximum signal intensity of magnevist contrast agent in modified t1 weighted spin echo, t1 weighted fast spin echo and t1 weighted gradient echo sequences
background: nowadays mri examinations have been widely used in clinical applications for many diagnoses. the use of contrast agent in mri improves lesion detection and characterization and causes more accurate diagnosis. objectives: the aim of this study was comparing to optimal dose of magnevist contrast agent in modified t1w se (spin echo), t1w fse (fast spin echo) and t1w gre (gradient ech...
متن کاملT1 CUBE compared to Fast Spin Echo T1 Weighted and BRAVO in post contrast enhanced brain MRI at 3T
ROW: The 2D FSE T1W and T1 CUBE images give superior depiction of the margins of this enhancing cerebellar tumor, in part because of greater CNR of contrast-enhancing tumor to adjacent cerebellar white matter. BOTTOM ROW: A channel of this venous angioma is best appreciated with the T1 CUBE, because of greater CNR relative to BRAVO and probably because of smaller section thickness relative to 2...
متن کاملEffect of Low Refocusing Angle in T1-Weighted Spin Echo and Fast Spin Echo MRI on Low-Contrast Detectability: A Comparative Phantom Study at 1.5 and 3 Tesla
MRI tissue contrast is not well preserved at high field. In this work, we used a phantom with known, intrinsic contrast (3.6%) for model tissue pairs to test the effects of low angle refocusing pulses and magnetization transfer from adjacent slices on intrinsic contrast at 1.5 and 3 Tesla. Only T1-weighted spin echo sequences were tested since for such sequences the contrast loss, tissue heatin...
متن کاملPerfusion MRI of the human brain with dynamic susceptibility contrast: gradient-echo versus spin-echo techniques.
In this study, spin-echo and gradient-echo-based perfusion magnetic resonance imaging (MRI) techniques are systematically compared with respect to their application in the human brain. Six healthy subjects were evaluated with both techniques consecutively and injected twice with a gadolinium-based contrast agent. In accordance with theoretical predictions and with previous animal experiments, t...
متن کاملcomparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences
conclusion using standard imaging parameters, each mri sequence reaches its maximum si in a specific contrast concentration, which is highest in se and least in ir in a comparison between se, fse and ir sequences. results this study shows that maximum si will appear at different ranges in different sequences. the maximum si can be seen at concentrations of 5.95, 4.96 and 3.98mmol/l for se, fse ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 2019
ISSN: 0369-4305,1881-4883