Improved Two-Level Voltage Source Converter for High-Voltage Direct Current Transmission Systems

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Ride-through Capability Enhancement of Voltage Source Converter-High Voltage Direct Current Systems with Bridge Type Fault Current Limiters

This paper proposes the use of bridge type fault current limiters (BFCLs) as a potential solution to reduce the impact of fault disturbance on voltage source converter-based high voltage DC (VSC-HVDC) systems. Since VSC-HVDC systems are vulnerable to faults, it is essential to enhance the fault ride-through (FRT) capability with auxiliary control devices like BFCLs. BFCL controllers have been d...

متن کامل

Distributed Voltage and Current Control of Multi-terminal High-voltage Direct Current Transmission Systems

High-voltage direct current (HVDC) is a commonly used technology for long-distance power transmission, due to its low resistive losses and low costs. In this paper, a novel distributed controller for multi-terminal HVDC (MTDC) systems is proposed. Under certain conditions on the controller gains, it is shown to stabilize the MTDC system. The controller is shown to always keep the voltages close...

متن کامل

High voltage gain DC-DC resonant converter

In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...

متن کامل

High voltage gain DC-DC resonant converter

In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Journal of Emerging and Selected Topics in Power Electronics

سال: 2017

ISSN: 2168-6777,2168-6785

DOI: 10.1109/jestpe.2017.2723839