Improved slice-selective adiabatic excitation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Composite Localization with adiabatic slice selective excitation and refocusing (cLASER) for improved 1H MRSI in non uniform B1 fields

INTRODUCTION: H magnetic resonance spectroscopic imaging (MRSI) can be used as a diagnostic tool to distinguish abnormal from normal tissue by obtaining metabolic information which can be used as biomarkers. MRSI can be improved by going to higher field strengths like 7 Tesla which offer increased spectral resolution and SNR. However, at these field strengths the non uniformity of the B1 field ...

متن کامل

A slice-selective B1-insensitive composite pulse design for improved excitation uniformity at 7 T

sub-pulses, each with 32 μs duration; (b) optimized phase modulation waveform; (c) simulated values of transverse magnetization for the optimized pulse over a range of relative B1 magnitudes (horizontal axis) and frequency offsets (vertical axis); (d) simulated frequency profiles for various relative B1 magnitudes. A slice-selective B1-insensitive composite pulse design for improved excitation ...

متن کامل

Improved Slice Profile and Reduced Fast Spin Echo Spacing with Variable-Rate Selective Excitation

The Variable-Rate Selective Excitation (VERSE) technique is shown to improve image quality by reducing fast spin echo spacing and improving slice profile. An algorithm was developed to use VERSE waveform reshaping to minimize echo spacing given specific prescription parameters and system constraints and was implemented for an SSFSE sequence to create shorter RF pulses with higher time•bandwidth...

متن کامل

Composite Slice-Selective 90' Excitation Pulses with Adiabaticity

Slice-selective adiabatic pulses are mostly confined to spin inversion and refocusing pulses. Here composite slice-selective 90" excitation pulses capable of multi-slice applications are proposed. This new class of pulses are based on halved adiabatic MIP pulses with each segment of the halved MIP pulses replaced by a small flip angle slice-selective plane rotation pulse such as a hamming-filte...

متن کامل

Mitigate B1+ inhomogeneity by slice-selective composite excitation pulses

Mitigate B1+ inhomogeneity by slice-selective composite excitation pulses Yi-Cheng Hsu, Ying-Hua Chu, Thomas Witzel, I-Liang Chern, and Fa-Hsuan Lin Department of Mathematics, Nnational Taiwan University, Taipei, Taiwan, Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan, A. A. Martinos Center, Massachusetts General Hospital, Charlestown, MA, United States, Departme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2013

ISSN: 0740-3194

DOI: 10.1002/mrm.24630