Improved scheduling algorithm for signal processing in asynchronous distributed ultrasonic total-focusing-method system
نویسندگان
چکیده
منابع مشابه
Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملDALD:-Distributed-Asynchronous-Local-Decontamination Algorithm in Arbitrary Graphs
Network environments always can be invaded by intruder agents. In networks where nodes are performing some computations, intruder agents might contaminate some nodes. Therefore, problem of decontaminating a network infected by intruder agents is one of the major problems in these networks. In this paper, we present a distributed asynchronous local algorithm for decontaminating a network. In mos...
متن کاملDigital Signal Processing System of Ultrasonic Signals
In general the ultrasonic testing is used for flaw detection and localization in tested materials. Flaws in materials are commonly characterized in measured ultrasonic signals by faults echoes. Ultrasonic signals measured on materials with coarse grained structure contain relative high level of noise. This undesirable part of ultrasonic signal should be reduced to make the fault echo detection ...
متن کاملA Signal Pre-processing Algorithm Applied for Ultrasonic Flow-meter
In order to solve the problem of time difference ultrasonic flow meter’s low accuracy, against the basic characteristics of the sample data, a data-processing algorithm is proposed. First, we use shell sort do a data pre-processing to the samples, then remove the error of the sample space by complex digital filter, and use the error compensation algorithm to get the final sample results. Among ...