Improved predictive direct power control of shunt active power filter using GWO and ALO – Simulation and experimental study

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل

Single-Phase Shunt Active Power Filter Using Indirect Control Method

A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...

متن کامل

Power System Harmonic Compensation Using Shunt Active Power Filter

This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...

متن کامل

Anti-windup Proportional Integral Strategy for Shunt Active Power Filter Interfaced by Photovoltaic System Using Technique of Direct Power Control

This paper focuses on power quality improvement in the distribution network using three phase shunt active power filter, where this later is connected to photovoltaic system. In the present work, a new control method has been presented to eliminate harmonic currents that is caused by nonlinear loads, and to compensate reactive power. This control method has a good accuracy and high efficiency, ...

متن کامل

Hybrid direct power/current control using feedback linearization of three-level four-leg voltage source shunt active power filter

Introduction The excessive use of power electronic equipments, which represent nonlinear loads, in a distribution network has caused many disturbances in the quality of power such as harmonic pollutions, unbalanced load currents, and reactive power problems. As a result poor power factor, weakening efficiency, overheating of motors and transformers, malfunction of sensitive devices etc. are enc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ain Shams Engineering Journal

سال: 2021

ISSN: 2090-4479

DOI: 10.1016/j.asej.2021.04.028