Improved particle identification using cluster counting in a full-length drift chamber prototype
نویسندگان
چکیده
منابع مشابه
Full-field drift Hamiltonian particle orbits in axisymmetric tokamak geometry
A Hamiltonian/Lagrangian theory to describe guiding center orbit drift motion that is canonical in Boozer magnetic coordinates is developed to include full electrostatic and electromagnetic perturbed fields in axisymmetric tokamak geometry. Furthermore, the radial component of the equilibrium magnetic field in the covariant representation is retained and the background equilibrium state extends...
متن کاملThe BaBar Drift Chamber
The central drift chamber for the BaBar detector at the PEP-II Bfactory at SLAC is a cylindrical chamber with a length of 280 cm and outer radius of 81 cm. It consists of 40 layers of small hexagonal cells arranged in 10 axial and stereo super-layers. In order to minimize multiple scattering, light materials are used for the mechanical structure, and the gas mixture is Helium based. The pulse-h...
متن کاملThe BaBar drift chamber project
The BaBar Drift Chamber is now under construction. We review its design, the progress in the construction of the components, the plan for assembly and stringing and we present test results obtained with a prototype exposed at SLAC to cosmic rays. We also report on projected dE/dx performance from beam tests done with a chamber with a different cell design. ( 1998 Published by Elsevier Science B...
متن کاملIntelligent identification and control using improved fuzzy particle swarm optimization
This paper presents a novel improved fuzzy particle swarm optimization (IFPSO) algorithm to the intelligent identification and control of a dynamic system. The proposed algorithm estimates optimally the parameters of system and controller by minimizing the mean of squared errors. The particle swarm optimization is enhanced intelligently by using a fuzzy inertia weight to rationally balance the ...
متن کاملBaBar drift chamber aging study
In order to obtain a reliable estimate of the lifetime of the BaBar drift chamber, a dedicated aging test chamber has been constructed. The working gas mixture is Helium/Isobutane (80/20). After accumulating up to 0.11C/cm charge dose the anode wire showed no appreciable signs of aging, but the field wires showed a small Malter effect. At 0.2C/cm the gas gain dropped B6–9% and the Malter effect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2014
ISSN: 0168-9002
DOI: 10.1016/j.nima.2013.09.028