Investigation of Harmonic Detection Techniques for Shunt Active Power Filter
Active power filters are used to eliminate current harmonics of non-linear loads. This paper evaluates three different methods of determining the compensating current for a shunt active filter that is working under nonsymmetrical conditions. The paper compares the instantaneous reactive power theory, the synchronous reference frame theory and fast Fourier transform techniques. The comparison is...
متن کاملHarmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter
With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...
متن کاملEfficient Hybrid Shunt Active Power Filter for Improvement of Power Factor and Harmonic Suppression using MATLAB
Power quality management is the main problem that the industry is facing today. This is mainly affected by the generation of harmonics. The growing use of electronic equipment produces a large amount of harmonics in distribution systems because of non-sinusoidal currents consumed by non-linear loads. As we know for the better quality of power, the voltage and current waveforms should be sinusoi...
متن کاملAn Improved Hybrid Active Power Filter for Power Quality Improvement in Three Phase Four Wire System
This paper presents a hybrid active power filter for a three phase four wire distribution system. The scheme consists of a zigzag transformer, single phase active power filter connected in series with the utility neutral and a coupling capacitor connected in series with a voltage source converter of the active power filter (APF). The addition of coupling capacitor permits the reduction in DC li...
متن کاملCurrent Harmonic Compensation and Power Factor Improvement by Hybrid Shunt Active Power Filter
In this paper the current harmonic can be compensated by using the Shunt Active Power Filter, Passive Power Filter and the combination of both. The system has the function of voltage stability, and harmonic suppression. The reference current can be calculated by dq transformation. An improved generalized integrator control was proposed to improve the performance of APF. The simulation results o...