Improved Low Power Multichannel Pulse Amplitude Analyzer
نویسندگان
چکیده
منابع مشابه
A Very Low-Cost Portable Multichannel Analyzer
A very low-cost portable Multichannel Analyzer (MCA) built with off-the-shelf commercial components is presented. Built around an universal microcontroller based platform for portable instruments, previously developed in our group, this intelligent portable MCA is operated by multicell Li-ion batteries and has power and memory autonomy for several hours of spectra collecting. The MCA integrates...
متن کاملThe Multichannel Analyzer
The multichannel analyzer (MCA) is an important laboratory instrument which can measure distributions of input signals consisting of pulses. It operates in two different modes: pulse height analyzer (PHA) mode, and multichannel scaler (MCS) mode. In PHA mode, the input pulses are sorted into bins (channels) according to their amplitude, while in MCS mode they are sorted according to the time wh...
متن کاملA multichannel continuous-flow analyzer.
A 10-channel analyzer is described with which sodium, potassium, chloride, carbon dioxide, calcium, phosphorus, total protein, albumin, albumin blank, and uric acid levels may be determined simultaneously. Operating at the rate of 60 specimens per hour, the instrument uses less than 1 ml. of serum for all 10 determinations. The results appear on 5 two-pen recorders. The report describes the ins...
متن کاملLow Power Pulse-Based Communication
Conclusion • Computer simulations have shown data transmission under low noise conditions • Testing of the transmitter and receiver have shown promising results • Timing issues are the most persistent problems • Despite these problems data was recovered successfully 1 1 0 1 0 1 Yellow: Incoming noisy pulses Green: Recovered digital data (110101) Purple: Output of the comparator circuit Blue: Th...
متن کاملLow-power, phase-preserving 2R amplitude regenerator
We propose a modification of a NALM-based 2R regenerator of phase-encoded signals which operates at considerably lower input powers than was studied earlier. Our modification consists of replacing the core-matched and lossless fiber coupler in the NALM by a coupler with a propagation constant mismatch and loss asymmetrically distributed between the two cores. The performance of the modified reg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: OALib
سال: 2020
ISSN: 2333-9721,2333-9705
DOI: 10.4236/oalib.1106629