Improved Decoupling for Low Frequency MRI Arrays Using Non-Conventional Preamplifier Impedance

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Low Input Impedance MRI Preamplifier Using a Purely Capacitive Feedback Network

R. Oppelt, M. Vester Corporate Technology, Siemens AG, Erlangen, Germany, Medical Solutions, Siemens AG, Erlangen, Germany Introduction: MRI preamplifiers need to meet a number of technical requirements that are not easily to be achieved simultaneously. Major challenges are a low noise figure (e.g. <= 0.5 dB), a stable gain and a high dynamic range. In addition, the small signal input impedance...

متن کامل

As a Low - Input - Impedance Preamplifier for Current - Division Use

By grounding the usual inputs of a 733 amplifier chip and driving one of the gain-control pins, one obtains a common-base input stage with an input impedance of about 20 ohms. This can be used as an inexpensive current-division preamp and, in large multichannel systems, will probably not limit the performance. In the current-division method of coordinate measurement one observes the (integrated...

متن کامل

Transmit Coil Decoupling of 8-Channel Coil Arrays with Ultra-Low Output Impedance RF Power Amplifiers

Introduction: In previous work, an ultra-low output impedance RF power amplifier (RFPA) was introduced to reduce the effects of inter-element inductive coupling in parallel transmit arrays [1]. It uses an output-matching network to transform the MOSFET drain-source impedance into a very low value to suppress inter-element coupling effects while matching the coil input impedance to the optimum l...

متن کامل

Non-invasive Imaging of Synchronized Neuronal Activity Using Low Frequency Electrical Impedance Tomography

Electrical impedance Tomography (EIT) has the potential to achieve non-invasive functional imaging of fast neuronal activity in the human brain. During evoked responses, fast (~1ms) local impedance changes of ~1% below 100Hz, were estimated to occur in our group using cable theory modelling and animal studies. The purpose of this work was to quantify the expected voltage changes in EIT potentia...

متن کامل

Understanding Power Impedance Supply for Optimum Decoupling

Noise in power supplies is not only caused by the power supply itself, but also the load’s interaction with the power supply (i.e. dynamic loads, switching, etc.). To lower load induced noise, most uninitiated designers use the biggest, lowest impedance capacitor that can be found, thinking that this will absorb the dynamic load current. This method is often hit and miss, and can even cause the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Biomedical Engineering

سال: 2019

ISSN: 0018-9294,1558-2531

DOI: 10.1109/tbme.2018.2881203