Improved analytical method to study the cup anemometer performance

نویسندگان
چکیده

منابع مشابه

On Cup Anemometer Rotor Aerodynamics

The influence of anemometer rotor shape parameters, such as the cups' front area or their center rotation radius on the anemometer's performance was analyzed. This analysis was based on calibrations performed on two different anemometers (one based on magnet system output signal, and the other one based on an opto-electronic system output signal), tested with 21 different rotors. The results we...

متن کامل

from linguistics to literature: a linguistic approach to the study of linguistic deviations in the turkish divan of shahriar

chapter i provides an overview of structural linguistics and touches upon the saussurean dichotomies with the final goal of exploring their relevance to the stylistic studies of literature. to provide evidence for the singificance of the study, chapter ii deals with the controversial issue of linguistics and literature, and presents opposing views which, at the same time, have been central to t...

15 صفحه اول

Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response

The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and fric...

متن کامل

Improved method for nondestructive measurement of dynamic pollen source strength from transgenic crops using sonic anemometer

Pollen-mediated gene flow from transgenic crops is a concern of the scientific community as well as the general public. Current lack is a nondestructive method to measure dynamic (hourly or shorter time period) source pollen release rate (source strength) from these crops. This paper reports an improved method using Rotorod concentration samplers and sticky slides, together with a fast response...

متن کامل

Analytical performance and method comparison study of the total homocysteine immunoassay on the AIA 600II analyser.

*Corresponding author: Cristina Novembrino, Laboratory of Clinical Chemistry and Microbiology, Fondazione IRCCS C à Granda Ospedale Maggiore Policlinico, via F. Sforza 35, 20122 Milano, Italy, Phone: + 39 0255033473, Fax: + 39 0255034571, E-mail: [email protected] Rachele De Giuseppe, Claudia De Vita and Fabrizia Bamonti: Department of Biomedical, Surgical and Dental Science...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Measurement Science and Technology

سال: 2015

ISSN: 0957-0233,1361-6501

DOI: 10.1088/0957-0233/26/10/107001