Improved Adaptive Robust Control for Low Voltage Ride-Through of Front-End Speed Regulation Wind Turbine

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficient low-voltage ride-through nonlinear backstepping control strategy for PMSG-based wind turbine during the grid faults

This paper presents a new nonlinear backstepping controller for a direct-driven permanent magnet synchronous generator-based wind turbine, which is connected to the power system via back-to-back converters. The proposed controller deals with maximum power point tracking (MPPT) in normal condition and enhances the low-voltage ride-through (LVRT) capability in fault conditions. In this method, to...

متن کامل

Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ride through (LVRT) and high voltage ride through (HVRT) capability of the DFIG WTGs. The characteristics of DFIG WTGs under voltage sags and s...

متن کامل

Voltage and Reactive Power Control of Front-end Speed Controlled Wind Turbine via H∞ Strategy

According to the characteristics like rapidity, time variability and the uncertainty of the input mechanical torque of front-end speed control wind turbine (FSCWT) with directly grid-connected and electrically excited synchronous generator (EESG), a double-loop H∞ control approach was proposed. In which, a simpilified structure of brushless excitation system was used. For the inner loop, first ...

متن کامل

Voltage Compensation Using UPQC For DFIG Wind Turbine Low - Voltage Ride - Through Solution

This paper describes the problem of voltage sags and swells and its severe impact on sensitive loads and introduces a new solution for doubly fed induction generators to stay connected to the grid during voltage sags. The main idea is to increase the stator voltage to a level that creates the required flux to keep the rotor side converter current below its transient rating. To accomplish this g...

متن کامل

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2020

ISSN: 2169-3536

DOI: 10.1109/access.2020.2980889