Improve X-ray Microanalysis in Variable-Pressure SEMs with Polycapillary X-ray Optics
نویسندگان
چکیده
منابع مشابه
Polycapillary X-ray optics for microdiffraction
Polycapillary optics, i.e. shaped arrays consisting of hundreds of thousands of hollow glass capillary tubes, can be used to redirect, collimate or focus X-ray beams. X-rays emitted over a large angular range from conventional laboratory-based sources can be transformed into a beam with a small angular divergence or focused onto a small sample or sample area. Convergent beams of X-rays, with co...
متن کاملFull-field transmission x-ray imaging with confocal polycapillary x-ray optics.
A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for his...
متن کاملGrid-enhanced X-ray coded aperture microscopy with polycapillary optics
Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10-100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imagin...
متن کاملX-Ray Microanalysis in the Variable Pressure (Environmental) Scanning Electron Microscope
Electron-excited x-ray microanalysis performed in the variable pressure and environmental scanning electron microscopes is subject to additional artifacts beyond those encountered in the conventional scanning electron microscope. Gas scattering leads to direct contributions to the spectrum from the environmental gas, as well as remote generation of x rays by electrons scattered out of the focus...
متن کاملAn X-ray polarimeter for hard X-ray optics
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer ...