Important Improvements of Helium Mass Spectrometry Test for Sealability
نویسندگان
چکیده
منابع مشابه
Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملUWFDM-1395 Improvements to the Helium Flow Path in the US DCLL ITER Test Blanket Module
Computational fluid dynamics simulations have demonstrated flow problems within the helium flow path in the current US DCLL ITER test blanket module design. New geometry for the helium flow path has been designed that will improve flow evenness and simplify the overall helium flow path within the test blanket module while maintaining the overall test blanket module geometry. Global changes to t...
متن کاملA mass spectrometry primer for mass spectrometry imaging.
Mass spectrometry imaging (MSI), a rapidly growing subfield of chemical imaging, employs mass spectrometry (MS) technologies to create single- and multi-dimensional localization maps for a variety of atoms and molecules. Complimentary to other imaging approaches, MSI provides high chemical specificity and broad analyte coverage. This powerful analytical toolset is capable of measuring the distr...
متن کاملCharge transfer dissociation (CTD) mass spectrometry of peptide cations using kiloelectronvolt helium cations.
A kiloelectronvolt beam of helium ions is used to ionize and fragment precursor peptide ions starting in the 1+ charge state. The electron affinity of helium cations (24.6 eV) exceeds the ionization potential of protonated peptides and can therefore be used to abstract an electron from--or charge exchange with--the isolated precursor ions. Kiloelectronvolt energies are used, (1) to overcome the...