Implementation of nuclear magnetic resonance polymer-gel dosimetry into clinical practice
نویسندگان
چکیده
منابع مشابه
Magnetic Resonance Elastography of Polymer Gel Dosimetry Phantoms
Introduction: Magnetic resonance imaging dependent polymer gel dosimetry is a technique that offers unique advantages for implementing increasingly complex radiotherapy procedures, due to the high spatial resolution and volumetric dosimetry capabilities. The technique involves the estimation of radiation dose distribution based on the changes in MR relaxation parameters caused by radiation indu...
متن کاملMagnetic resonance in polymer gel dosimetry: techniques and optimization
1. Introduction Magnetic resonance imaging (MRI) can non-invasively and non-destructively probe the magnetization of hydrogen atoms on water molecules in large objects with a high spatial resolution, and in three dimensions. This unique combination of properties is exploited in polymer gel dosimetry since original gel dosimeters, in which viscosity changes were measured and related to the absor...
متن کاملEvaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.
A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detecto...
متن کاملMagnetic-Resonance-Imaging based Polymer Gel Dosimetry: Methodology, Spatial Resolution, Applications
Modern radiation techniques aim on improved 3-dimensional (3D) spatial selectivity of the dose application sparing dose from organs-at-risk (e.g. IMRT with micro-multileaf collimation, γ-knife-, Brachyand heavy-ion therapy). The corresponding 3D-dose distributions exhibit high dose gradients above 4 Gy/mm, which are difficult to be investigated using standard single-point dosimetric detectors ...
متن کاملVerification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging
Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2003
ISSN: 0094-2405