Implant/abutment vertical misfit of one-piece cast frameworks made with different materials.

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was meas...

متن کامل

Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

PURPOSE Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The fram...

متن کامل

Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment

OBJECTIVES The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, i...

متن کامل

Fit Analysis of Different Framework Fabrication Techniques for Implant-Supported Partial Prostheses.

PURPOSE This study evaluated the vertical misfit of implant-supported frameworks made using different techniques to obtain passive fit. MATERIALS AND METHODS Thirty three-unit fixed partial dentures were fabricated in cobalt-chromium alloy (n = 10) using three fabrication methods: one-piece casting, framework cemented on prepared abutments, and laser welding. The vertical misfit between the f...

متن کامل

Fluid-structure Interaction Vibration Analysis of Vertical Cylindrical Containers with Elastic Bottom Plate Made of Functionally Graded Materials

In the present paper a method is proposed to investigate the free vibration of a partially liquid-filled cylindrical tank. The mechanical properties of the container are assumed to change continuously along the thickness according to volume fraction Power-law, Sigmoid or Exponential distribution. The liquid is supposed to be incompressible and in viscid and its velocity potential is formulated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Brazilian Dental Journal

سال: 2010

ISSN: 0103-6440

DOI: 10.1590/s0103-64402010000600006