Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Therapy

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac resynchronization therapy with and without implantable cardioverter-defibrillator.

Cardiac resynchronization therapy (CRT) is recommended to reduce morbidity and mortality in patients with New York Heart Association class III/IV, who are symptomatic despite optimal medical therapy, and who had a reduced left ventricle (LV) ejection fraction and electrical dyssynchrony. The effects of CRT are reflected mainly by the degree and location of dyssynchrony and by working in inserti...

متن کامل

Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.

Inappropriate shocks from implantable cardioverter-defibrillators (ICDs) may occur for many reasons. Inappropriate shocks are not simply painful inconveniences for patients; they also may result in the need for further operative procedures, and sometimes even death. Herein, we report the case of a patient who after upgrade of an ICD to a cardiac resynchronization therapy-defibrillator device (C...

متن کامل

Survival After Shock Therapy in Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Therapy-Defibrillator Recipients According to Rhythm Shocked

Survival After Shock Therapy in Implantable Cardioverter-Defibrillator and Cardiac Resynchronization Therapy-Defibrillator Recipients According to Rhythm Shocked The ALTITUDE Survival by Rhythm Study Brian D. Powell, MD,* Leslie A. Saxon, MD,y John P. Boehmer, MD,z John D. Day, MD,x F. Roosevelt Gilliam III, MD,k Paul A. Heidenreich, MD, MS,{ Paul W. Jones, MS,# Matthew J. Rousseau, MS,# David ...

متن کامل

Loss of cardiac resynchronization therapy in a patient with a biventricular implantable cardioverter-defibrillator

Here, we discuss the case of a man with a history of ischemic cardiomyopathy and cardiac resynchronization therapy defibrillator implantation, who presented to emergency department with decompensated heart failure due to the loss of resynchronization therapy. The reason for the malfunction was left ventricle upper rate interval lock-in due to inappropriate programming of the device.

متن کامل

Inappropriate Shock Delivered By Implantable Cardioverter Defibrillator - Cardiac Resynchronization Therapy (ICD-CRT) Due To Myopotential Oversensing

The clinical efficacy of ICD-CRT therapy depends on accurate sensing of intracardiac signals and sensing algorithms. We report the occurrence of sensing abnormality in a patient with ICD-CRT. In this patient, oversensing of myopotentials during strenuous muscular activity resulted in an inappropriate ICD-CRT discharge. Although modern ICDs are highly effective in detecting and terminating malig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Korean Journal of Medicine

سال: 2016

ISSN: 1738-9364,2289-0769

DOI: 10.3904/kjm.2016.90.3.210