Imperfection-sensitivity of unanchored aboveground open-top steel welded liquid storage tanks subjected to seismic loads

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity analysis of pile-founded fixed steel jacket platforms subjected to seismic loads

The sensitivity of the seismic response parameters to the uncertain modeling variables of pile-founded fixed steel jacket platforms are investigated using the Tornado diagram and the first-order second-moment techniques. The effects of both aleatory and epistemic uncertainty on seismic response parameters have been investigated for an existing offshore platform. The sources of uncertainty consi...

متن کامل

Seismic Rehabilitation of Liquid Storage Tanks using Friction Pendulum Base Isolation subjected to the Near-Fault Ground Motions

Cylindrical liquid storage tanks are considered as vital structures in industrial complex whose nonlinear dynamic behavior is of crucial importance. Some of these structures around the world have demonstrated poor seismic behavior over the last decades. There are several methods and techniques for rehabilitation and reducing damages in these structures which among them passive control devices, ...

متن کامل

Behavior of Steel-Sheathed Shear Walls Subjected to Seismic and Fire Loads.

A series of tests was conducted on six 2.7 m × 3.7 m shear wall specimens consisting of cold-formed steel framing sheathed on one side with sheet steel adhered to gypsum board and on the opposite side with plain gypsum board. The specimens were subjected to various sequences of simulated seismic shear deformation and fire exposure to study the influence of multi-hazard interactions on the later...

متن کامل

Improving seismic performance of elevated cylindrical water storage tanks using nonlinear isolators incorporating liquid–structure interaction

Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the necessity for research toward new passive control devices. Design and use of base-isolation systems for elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relati...

متن کامل

Buckling of Aboveground Storage Tanks with Conical Roof

The buckling of aboveground circular steel tanks with conical roof is considered in this paper. The specific source of loads investigated is wind action during hurricane storms in the Caribbean islands. The structure is modeled using a finite element discretization with the computer package ALGOR. Bifurcation buckling of the shell is computed for a given static wind pressure distribution. Then ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: SN Applied Sciences

سال: 2019

ISSN: 2523-3963,2523-3971

DOI: 10.1007/s42452-019-1597-7