Impedance plethysmography revisited
نویسندگان
چکیده
منابع مشابه
Implantable Impedance Plethysmography
We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.
متن کاملLimitations of electric impedance plethysmography.
Klectrie impedance plethysmography has been offered as a substitute for mechanical plethysmography and would be particularly suitable for regions in which the mechanical method cannot be applied. A comparative investigation of mechanical and impedance plethysmograms, taken simultaneously from a finger or a forearm, revealed that, while the normal pulsations were reproduced reasonably well, elec...
متن کاملImpedance Control of Robots Using Voltage Control Strategy Revisited
In this note, we show that the impedance control strategy proposed in the paper is not feasible from practical implementation point of view. Next, a robust impedance controller is proposed for electrically driven robots using Fourier series (FS). The fact that robots' actuators have limited voltage is also considered in controller design procedure. In comparison with other impedance controllers...
متن کاملBioelectrical impedance analysis revisited.
Although total limb volume measurements are used to track the progress of lymphedema and its treatment, these measurements can be confounded by changes other than fluid excess namely muscle or fat gain. Bioelectrical impedance analysis (BIA) is a technique that specifically quantifies both total body fluid and extracellular fluid in extremities. Whereas BIA has potential as a quick, inexpensive...
متن کاملImpedance cardiography revisited.
UNLABELLED Previously reported comparisons between cardiac output (CO) results in patients with cardiac conditions measured by thoracic impedance cardiography (TIC) versus thermodilution (TD) reveal upper and lower limits of agreement with two standard deviations (2SD) of approximately +/-2.2 l min(-1), a 44% disparity between the two technologies. We show here that if the electrodes are placed...