Impedance Modeling and Analysis of Medium-Frequency Oscillation Caused by VSC-HVDC Connected to Local Weak Grid and DFIG-Based Wind Farms

نویسندگان

چکیده

In the northwest of China, a strategy to transmit wind-thermal–bundled power from local grid and doubly fed induction generator (DFIG)–based wind farms through voltage source converter–based HVDC (VSC-HVDC) can be widely applied. However, since is usually weak, new type electrical oscillation in medium-frequency region may occur sending-end converter (SEC) VSC-HVDC with PQ-control. The mechanism this caused by interaction between DFIG, grid, SEC not entirely understood. study, sequence impedance model PQ-control outer loop PLL derived explicit analytic expression, then, explored based on intuitive analysis system frequency characteristics. Compared subsynchronous (SSO) DFIG or inverter, theoretical shows that (MFO) mainly originates due its negative damping effect about 100 200 Hz. addition, impact controller parameters operating conditions characteristics analyzed detail. Finally, correctness validated time-domain simulation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of DFIG Based Offshore Wind Farms Connected Through VSC-HVDC Link on Power System Stability

With the increased levels of offshore wind power penetration into power systems, the impact of offshore wind power on stability of power systems require more investigation. In this paper, the effects of a large scale doubly fed induction generator (DFIG) based offshore wind farm (OWF) on power system stability are examined. The OWF is connected to the main onshore grid through a voltage source ...

متن کامل

Small Signal Stability Analysis for a DFIG-Based Offshore Wind Farms Collected Through VSC-HVDC Transmission System

This paper modeled a doubly fed induction generator (DFIG) based offshore wind farm integrated through a voltage source converter –based high voltage direct current (VSC-HVDC) transmission system, which is collected with infinite bus for small signal stability analysis. The control system of HVDC system is considered for the stability analysis. The impact of the VSC control parameters on the ne...

متن کامل

Stability Analysis of Four Parallel-Operated DFIG-based Offshore Wind Farms Fed to a Large Power Grid Through a VSC-HVDC Link

This paper presents the analyzed results of using a high-voltage directcurrent (HVDC) link based on voltage-source converter (VSC) to achieve damping improvement of four parallel-operated doubly-fed induction generator (DFIG)-based offshore wind farms (OWFs) fed to a large power grid. A frequency-domain scheme based on eigenvalue analysis is carried out and a time-domain method based on nonline...

متن کامل

Dynamic Harmonic Modeling and Analysis of VSC-HVDC Systems

Harmonics have become an important issue in modern power systems. The widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. This paper employs a Dynamic Harmonic Domain (DHD) based framework for dynamic harmonic analysis of VSC-HVDC systems. These systems are wide...

متن کامل

Analysis and simulation of dynamic performance for DFIG-based wind farm connected to a distrubition system

Local renewable resources such as wind and solar are often available in remote locations. Wind farms consist of many individual wind turbines which are connected to the electric power transm­iss­i­o­n ne­tw­o­r­k­. A wind farm can use the wind resources from a certain area efficiently. Double-fed induction generator (DFIG) is a gene­rating principle widely used in wind turbine (WT). DFIG are ab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Frontiers in Energy Research

سال: 2021

ISSN: ['2296-598X']

DOI: https://doi.org/10.3389/fenrg.2021.693903