Impedance and impulse response measurements using low‐cost components
نویسندگان
چکیده
منابع مشابه
Impulse Response Measurements Using All-Pass Deconvolution
A method of measuring impulse responses of rooms will be described which uses time reversed electronic reverberation from a single pulse as the excitation. The room response, recorded on DAT, is decoded by playing the tape back through the reverberator. The output can be heard, recorded, or analyzed. The method improves S/N by 20 dB and can be implemented with approximately 14 multiples/sample ...
متن کاملCole equation modelling to measurements made using an impulse driven transfer impedance system.
Electrical impedance measurements are used to obtain information about a subject, tissue sample or tissue model under test. There are several ways of obtaining these impedance data and thereafter analysing the data to obtain relevant parameters. This paper shows how a completely isolated drive and receive system using current pulses, as opposed to sine waves, achieves good fitted results with r...
متن کاملImpedance-type measurements using XPS
An impedance type of measurement using X-ray photoelectron spectroscopy is applied for probing charging/discharging dynamics of a sample containing Rb deposited on a SiO2/Si substrate containing an octadecyltrichlorosilane (OTS) bilayer coating. The OTS bilayer coatings have possible use as antirelaxationwall coatings for alkali atom vapor cells inminiaturized instruments such as chip-scale ato...
متن کاملStructural health monitoring using piezoelectric impedance measurements.
This paper presents an overview and recent advances in impedance-based structural health monitoring. The basic principle behind this technique is to apply high-frequency structural excitations (typically greater than 30kHz) through surface-bonded piezoelectric transducers, and measure the impedance of structures by monitoring the current and voltage applied to the piezoelectric transducers. Cha...
متن کاملDetermination of Sound Reduction Index by impulse response measurements
The Sound Reduction Index of a partition can be measured according to the method described by ISO 140. This paper reports experimental results obtained with a new measurement method based on the determination of the impulse response in two rooms separated by the partition. In fact, it is possible to show that, by evaluating the Schroeder integral plot, we can calculate energy levels and reverbe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Acoustical Society of America
سال: 1982
ISSN: 0001-4966
DOI: 10.1121/1.2019992