Impacts of Symmetrical and Asymmetrical Voltage Sags on DFIG-Based Wind Turbines Considering Phase-Angle Jump, Voltage Recovery, and Sag Parameters
نویسندگان
چکیده
منابع مشابه
New Detection of Voltage Sag Based on Phase Angle Analysis
Voltage sag compensator is very important in power quality. Its performance also depends on the types of sag detection techniques used. Sag detection technique determines the dynamic performance of a voltage-sag compensator. Many techniques have been introduced to measure and to detect voltage sag, such as RMS-Value Evaluation and Peak-Value Evaluation. Unfortunately, most of the techniques req...
متن کاملLow voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips
This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIGbased wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced ...
متن کاملDynamic Performance Of DFIG Based WECS Under Different Voltage Sag
At the present time Doubly Fed Induction Generator (DFIG) based wind energy conversion systems are widely used for large wind power plants. DFIG offers many advantages for instance reduced rating power converter, low cost and reduced losses with the better efficiency, easy in realization of power factor correction schemes, variable speed operation and four quadrants active and reactive power co...
متن کاملEvaluation of Voltage Flicker Emissions of Variable Speed Dfig-based Wind Turbines
Wind-energy systems cause fluctuations more than any other sources and hence, voltage fluctuations are expected with these units. This paper addresses the problem of voltage fluctuation caused by doubly fed induction generators (DFIG)-based variable-speed wind turbines. Flicker emission of these units is investigated during continuous operation. The effects of grid strength, angle of grid imped...
متن کاملStudy of Self-Tuning PI Controllers in a Constant Voltage Control System for Doubly-fed Wind Turbines
The doubly-fed induction generator (DFIG) produces the reactive power to maintain its constant voltage operation. Firstly, the principle of the constant voltage control system for double-fed wind turbines is researched, and the influence on DFIG terminal voltage when the wind speed changes and the grid voltage sags is analyzed. Secondly, self-tuning PI control algorithm based on BP neural netwo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Power Electronics
سال: 2011
ISSN: 0885-8993,1941-0107
DOI: 10.1109/tpel.2010.2087771