Impact of Xylose on Glucose-Dehydrogenase-Based Blood Glucose Meters for Patient Self-Testing
نویسندگان
چکیده
منابع مشابه
Hematocrit interference of blood glucose meters for patient self-measurement.
BACKGROUND Abnormal hematocrit levels may interfere with glucose readings of patient self-assessment blood glucose (BG) meters. The aim of this laboratory investigation was to assess the potential influence of hematocrit variations on a variety of BG meters applying different measurement technologies. METHODS Venous heparinized blood was manipulated to contain three different BG concentration...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملVariability of blood glucose meters for patient self-testing: analysis of the article by Brazg and coauthors.
The article by Brzag and coauthors in this issue of Journal of Diabetes Science and Technology reports a competitive accuracy performance study for a branded meter in comparison with six low-cost meters currently available in the United States. It highlights several important topics: (1) the need for more stringent post-marketing requirements for blood glucose meters after launch and (2) low-co...
متن کاملPredicted blood glucose from insulin administration based on values from miscoded glucose meters.
OBJECTIVES The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205-210, 2007). It attempts to relate potential insulin dose errors to possible...
متن کاملEvaluation of hematocrit bias on blood glucose measurement with six different portable glucose meters.
INTRODUCTION Measurement and monitoring of blood glucose levels in hospitalized patients with portable glucose meters (PGMs) is performed widely and is an essential part of diabetes monitoring, despite the increasing evidence of several interferences which can negatively bias the accuracy of measurements. The purpose of this study was to evaluate the effect of the hematocrit on the analytical p...