Impact of Wall Configurations on Seismic Fragility of Steel-Sheathed Cold-Formed Steel-Framed Buildings
نویسندگان
چکیده
منابع مشابه
Analysis of Sheathed Cold-Formed Steel Wall Studs
The strength of sheathed wall systems is substantially greater than unsheathed walls with the same studs. Testing on studs sheathed on both sides with dry gypsum board demonstrate strength increases as large as 70% over unsheathed studs (Miller and Peköz 1993, Miller and Peköz 1994). The current AISI Specification for sheathed wall stud systems are complicated, only apply when the sheathing is ...
متن کاملModeling the seismic response of cold-formed steel framed buildings: model development for the CFS-NEES building
The objective of this paper is to investigate the response of a cold-formed steel framed building subjected to earthquake excitation primarily through nonlinear time history analysis employing the incremental dynamic analysis (IDA) framework. The two-story archetype building from the Cold-Formed Steel – Network for Earthquake Engineering Simulation (CFS-NEES) project is analyzed using OpenSees....
متن کاملSeismic design of multi - story cold - formed steel buildings : the CFS - NEES archetype building
Lightweight cold-formed steel (CFS) framing is an effective building solution for low and mid-rise structures. However, systems level response and component contributions as well as their interactions such as those from lateral-load resisting systems, floor diaphragms, studs to track connections, etc., are not fully understood. Existing building codes for the CFS frame buildings are based solel...
متن کاملOn Cold-Formed Steel Construction
Powder-actuated (also referred to as low velocity or powder-driven) fasteners are commonly used to attach cold-formed steel framing members, usually a track, to a concrete or structural steel support. Although commonly used, their behavior is less well understood than other fasteners such as screws, bolts and welds. The AISI Cold-Formed Steel Design Manual does not explicitly address powder act...
متن کاملExperimental Investigation on Cold-formed Steel Wall Plate System
A series of tests on cold-formed steel (CFS) wall plate system subjected to uplift force at the mid span of the wall plate is presented. The aim of the study was to study the behaviour and identify the modes of failure of CFS wall plate system. Two parameters were considered in these studies: 1) different dimension of U-bracket at the supports and 2) different sizes of lipped Cchannel. The lipp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Civil Engineering
سال: 2018
ISSN: 1687-8086,1687-8094
DOI: 10.1155/2018/2528549