Impact of Inertia Emulation Based Modified HVDC Tie-Line for AGC Using Novel Cascaded Fractional Order Controller in Deregulated Hybrid Power System
نویسندگان
چکیده
This article deals with the Automatic Generation Control (AGC) mechanism for an interconnected, deregulated hybrid power system. The physical generation constraints such as boiler dynamics, governor dead band (GDB) and rate (GRC) are included a more realistic approach. integration of distributed (DG) systems is also considered to match present scenario. intermittency nature DGs ruins system's inertia dynamic behaviour. A novel cascaded fractional order controller configuration 2-DOF (FOPIλDN)-PDN proposed AGC new quasi opposition based volleyball premier league (QVPL) algorithm employed optimize gains. On other hand, emulation strategy (IES) modified HVDC tie-line used parallel AC retrace inertia. impact IES has been analysed by subjecting several case studies. effectiveness QVPL tested comparing it previously published works on same platform.
منابع مشابه
Decentralized Fractional Order PID Controller for AGC in a Multi Area Deregulated power system
This paper presents the application of Fractional Order PID controller as a supplementary controller to improve the dynamics of LFC in multi area deregulated power system. FOPID is a PID controller whose derivative and integral orders are of fractional rather than integer. The extension of derivative and integration order from integer to fractional order provides more flexibility in design of t...
متن کاملA Fuzzy Sliding Mode Controller for AGC of Multi Area Deregulated Power System
Two problems: Parameter uncertainty and chattering effect present in Control signal are have a great deal in performance of system with the designed controllers. This paper presents Fuzzy Sliding Mode Controller (FSMC) for Multi Area Load Frequency Control problem or Automatic Generation Control (AGC) in a De-regulated environment. The first problem is addressed by designing a sliding mode cont...
متن کاملDesign of a Model Reference Adaptive Controller Using Modified MIT Rule for a Second Order System
Sometimes conventional feedback controllers may not perform well online because of the variation in process dynamics due to nonlinear actuators, changes in environmental conditions and variation in the character of the disturbances. To overcome the above problem, this paper deals with the designing of a controller for a second order system with Model Reference Adaptive Control (MRAC) scheme usi...
متن کاملCongestion Management in Deregulated Power System using Facts Controller
Congestion in the transmission lines is one of the technical problems that appear particularly in the deregulated environment. There are two types of congestion management methodologies to relieve it. One is non-cost free methods and another is cost-free methods, among them later method relieves the congestion technically whereas the former is related with the economics. In this paper congestio...
متن کاملHVDC-based Fast Frequency Support for Low Inertia Power Systems
This paper analyses and compares different methodologies for supporting system frequency in low inertia power systems using HVDC interconnectors. Reduced system inertia, caused by the massive integration of converter-interfaced renewables and the displacement of conventional synchronous generation, can result in high values of rate of change of frequency (ROCOF), increasing the risk of frequenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electrical Engineering & Technology
سال: 2021
ISSN: ['1975-0102', '2093-7423']