Imaging Modalities for Diagnosis of Deep Pelvic Endometriosis: Comparison between Trans-Vaginal Sonography, Rectal Endoscopy Sonography and Magnetic Resonance Imaging. A Head-to-Head Meta-Analysis
نویسندگان
چکیده
منابع مشابه
O-19: A Comparison of Pelvic Magnetic Resonance Imaging, Trans-Vaginal and Trans-Rectal Sonography with Laparoscopic Findings in The Diagnosis of Deep Infiltrating Endometriosis
Background The performance of TVS, TRS and MRI for the diagnosis of DIE have been separately reported in earlier studies. However, the three methods have not been concurrently compared in terms of their overall performance and classified results as per different anatomical locations of DIE lesions in a large study population. This study was an attempt to compare pelvic magnetic resonance imagin...
متن کاملComparison between transvaginal sonography, sonovaginography and magnetic resonance imaging in the diagnosis of posterior deep infiltrating endometriosis
Results Fifty-four patients out of 102 women suspected of having posterior DPE underwent laparoscopic surgery. Among these, in 46 (85.2%) cases DPE was confirmed at laparoscopic and histological examination. Sonovaginography correctly identified 43 (93.5%) cases, presenting higher accuracy than did the other procedures. Sonovaginography and MRI were more accurate in diagnosing and discriminatin...
متن کاملTransvaginal sonography and rectal endoscopic sonography for the assessment of pelvic endometriosis: a preliminary comparison.
BACKGROUND Endometriosis and possible rectal involvement are difficult to assess by physical examination. Previous studies have shown the diagnostic value of magnetic resonance imaging and rectal endoscopic sonography (RES) in this setting, but not that of transvaginal sonography (TVS). The aims of this study were to compare the accuracy of TVS and RES for the diagnosis of pelvic endometriosis,...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Diagnostics
سال: 2019
ISSN: 2075-4418
DOI: 10.3390/diagnostics9040225