IMAGE QUALITY OF T2W TSE CARTESIAN VERSUS T2W TSE BLADE, A QUANTITATIVE ANALYSIS ON AXIAL CERVICAL MRI

نویسندگان

چکیده

Backgroud: blurring artifact is an issue in axial cervical MRI using T2 Turbo Spin Echo (TSE) weighted Cartesian. T2W TSE BLADE potential to substitute its shortcomings. This study aims analyze the image quality and artifacts between Cartesian on examination determine better sequence producing quality.Methods: this a quantitative research with descriptive approach. 7 volunteers were scanned for TSE, Blade. Images processed MathlabTM. SNR of intervertebral disc, spinal cord CSF measured ROI. Image resolution find out from pixel spacing DICOM info. Blurring analyzed by comparing signal blurred area background noise. Data statistics.Results: 22,144 17,532 (intervertebral disc), 20,952 16,786 (spinal cord), 16,717 12,883 (CSF) respectively. (mean) 0,391 pixel/mm (T2W Cartesian) 0,625 BLADE). 8,161 6,826 Blade).Conclusion: was superior intensity SNR, while blade technique terms spatial reduction. Thus, it recommended be applied clinical field if or detail priority.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Should less motion sensitive T2-weighted BLADE TSE replace Cartesian TSE for female pelvic MRI?

OBJECTIVES To prospectively compare the diagnostic performance of a non-Cartesian k-space sampling T2-weighted TSE BLADE sequence with a conventional T2-weighted TSE sequence in female pelvic organs. METHODS Forty-seven patients with sonographically indeterminate adnexal masses or uterine lesions underwent sagittal BLADE and conventional TSE at 1.5 T after glucagon administration. Two radiolo...

متن کامل

Dual Contrast 3D-TSE, T2w and FLAIR imaging at 7.0 Tesla

Introduction: Multi slice T2w-TSE and FLAIR-TSE sequences are two of the most important techniques in neuro-radiology. The problem of partial volume effects and inherent CSF-inflow artifacts in FLAIR can be resolved by using a non-selective 3D-TSE acquisition technique with advanced refocusing pulse angle sweep [1]. A disadvantage of 3D TSE sequences with isotropic voxel size smaller than 1mm i...

متن کامل

Evaluation of Aqueductal Patency in Patients with Hydrocephalus: Three-Dimensional High-Sampling-Efficiency Technique (SPACE) versus Two-Dimensional Turbo Spin Echo at 3 Tesla

OBJECTIVE To compare the accuracy of diagnosing aqueductal patency and image quality between high spatial resolution three-dimensional (3D) high-sampling-efficiency technique (sampling perfection with application optimized contrast using different flip angle evolutions [SPACE]) and T2-weighted (T2W) two-dimensional (2D) turbo spin echo (TSE) at 3-T in patients with hydrocephalus. MATERIALS AN...

متن کامل

EMPIRICAL ANALYSIS ON TSE DATAc

WHAT MAKES SPECULATORS TO TRADE MORE OFTEN? EMPIRICAL ANALYSIS ON TSE DATA Abstract In this paper we investigate, how the value of transaction costs (TC) and the frequency of investment decision-making can influence the perception of market efficiency. The profit performance of four types of investors is evaluated under the schedule of TC. Hypothetical results for several high-frequency time se...

متن کامل

Small Malignant Hepatic Tumor Detection in Gadolinium- and Ferucarbotran-Enhanced Magnetic Resonance Imaging: does Combining Ferucarbotran-Enhanced T2*-Weighted Gradient Echo and T2-Weighted Turbo Spin Echo Images have Additive Efficacy?

OBJECTIVE To determine if a combination of ferucarbotran-enhanced T2*weighted-gradient echo (T2*W-GRE) and T2-weighted turbo spin echo (T2W-TSE) images in gadolinium- and ferucarbotran-enhanced MRI has additive efficacy compared to each image alone for detecting small (< or = 2.0 cm) hepatocellular carcinoma (HCC) lesions in a group of cirrhotic patients and metastases in a group of non-cirrhot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Jurnal Imejing Diagnostik

سال: 2022

ISSN: ['2356-301X', '2621-7457']

DOI: https://doi.org/10.31983/jimed.v8i2.8955