Illuminance Calculation in partially obstructed room by monte carlo method
نویسندگان
چکیده
منابع مشابه
Direct Lighting Calculation by Monte Carlo Integration
The details of doing a Monte Carlo direct lighting calculation are presented. For direct lighting from multiple luminaires, a method of sending one shadow ray per viewing ray is presented, and it is argued that this is preferable for scenes with many luminaires. Some issues of the design of probability densities on unions of luminaire surfaces are discussed.
متن کاملMonte Carlo Renormalization Group Calculation in Λφ
We start by discussing some theoretical issues of renormalization group transformations and Monte Carlo renormalization group technique. A method to compute the anomalous dimension is proposed and investigated. As an application, we find excellent values for critical exponents in λφ43. Some technical questions regarding the hybrid algorithm and strong coupling expansions, used to compute the cr...
متن کاملA method for range calculation of proton in liquid water: Validation study using Monte Carlo method and NIST data
Introduction: The main advantage of using ion beams over photons in radiotherapy is due to their inverse depth-dose profiles, allowing higher doses to tumors, while better sparing normal tissues. When calculating dose distributions with ion beams, one crucial point is the uncertainty of the Bragg-peak range. Recently great effort is devoted to enhance the accuracy of the comput...
متن کاملEfficient inductance calculation in interconnect structures by applying the Monte Carlo method
We present an advanced algorithm for an extraction tool to compute inductances of interconnect structures. As already pointed out [Proc. Third Int. Conf. Modeling Simul. Microsyst. (2000) 416] the pursued energy concept leads to a 6-fold integral which can also be evaluated by use of the Monte Carlo method. A classical implementation of the Monte Carlo method, where the whole geometry has to be...
متن کاملMonte-Carlo Calculation of Radon Absorbed Dose in Optical Fiber as a Novel Method in Dosimetry and Radon Measurement
Introduction Radon is a colorless and tasteless gas which exists in most soils. It is a substance that poses a potential risk for lung cancer in case a person is exposed to high levels over long periods of time. The Environmental Protection Agency (EPA) estimates that 90% of lung cancers per year are caused by radon. The aim of this paper is to estimate the absorbed doses of 222Rn by MCNPX simu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Illuminating Engineering Institute of Japan
سال: 1987
ISSN: 0019-2341,1349-838X,2185-1506
DOI: 10.2150/jieij1980.71.appendix_56