Identification of Staphylococcus species of bovine origin with the API Staph-Ident system
نویسندگان
چکیده
منابع مشابه
Identification of Staphylococcus species of bovine origin with the API Staph-Ident system.
The API Staph-Ident system was evaluated as a means for identifying the species of bovine strains of staphylococci routinely isolated from quarter-milk samples. The species identity of 314 of 581 (54%) isolates of staphylococci was correctly determined by this method. The API Staph-Ident system was more accurate in correctly identifying Staphylococcus aureus (93.9%) than in correctly identifyin...
متن کاملIdentification of Staphylococcus species with the API STAPH-IDENT system.
The API STAPH-IDENT system was compared with conventional methods for the identification of 14 Staphylococcus species. Conventional methods included the Kloos and Schleifer simplified scheme and DNA-DNA hybridization. The API STAPH-IDENT strip utilizes a battery of 10 miniaturized biochemical tests, including alkaline phosphatase, urease, beta-glucosidase, beta-glucuronidase, and beta-galactosi...
متن کاملIdentification of Staphylococcus species of bovine origin with the DMS Staph-Trac system.
The DMS Staph-Trac system was evaluated as a means for identifying the species of bovine strains of staphylococci routinely isolated from quarter-milk samples. The species identity of 83 of 91 (91.2%) isolates of staphylococci was correctly determined by this method. One isolate could not be identified by this system. The Staph-Trac system was able to distinguish between Staphylococcus hyicus a...
متن کاملComparison of the MicroScan system with the API Staph-Ident system for species identification of coagulase-negative staphylococci.
To evaluate the accuracy of the MicroScan System (American Hospital Supply Corp., Sacramento, Calif.) for identification of coagulase-negative staphylococci, we tested 175 clinical isolates of coagulase-negative staphylococci. The results obtained by the MicroScan system were compared with those of the API Staph-Ident system (Analytab Products, Plainview, N.Y.). Forty-three discrepancies betwee...
متن کاملIdentification of coagulase-negative staphylococci with the API STAPH-IDENT system.
A group of 300 clinically derived isolates of coagulase-negative staphylococci were tested in parallel with the API STAPH-IDENT system (Analytab Products) and 14 conventional biochemical tests contained in Kloos and Schleifer's simplified scheme for identification of human Staphylococcus species. STAPH-IDENT is a miniaturized biochemical test strip that incorporates four synthetic chromogenic s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Microbiology
سال: 1983
ISSN: 0095-1137,1098-660X
DOI: 10.1128/jcm.18.5.1212-1219.1983