Identification of epidural space using air and normal saline
نویسندگان
چکیده
منابع مشابه
Identification of the epidural space: stop using the loss of resistance to air technique!
In a prospective trial involving 547 women, Evron et al. reported a 16% incidence of difficult epidural catheter insertion following a LOR with air technique, while in those patients treated with fluid for the LOR only 4% had a difficult catheter insertion (13). Evron et al. also showed that with air more inadvertent intravascular insertions of the epidural catheter occurred (13). This was howe...
متن کاملsynthesis of amido alkylnaphthols using nano-magnetic particles and surfactants
we used dbsa and nano-magnetic for the synthesis of amido alkylnaphtols.
15 صفحه اولSuccess of spinal and epidural labor analgesia: comparison of loss of resistance technique using air versus saline in combined spinal-epidural labor analgesia technique.
BACKGROUND Comparison of air versus saline for loss of resistance technique (LORT) in combined spinal epidural labor analgesia (CSE) has not been evaluated, and neither has the relation between CSE characteristics (the presence/absence of initial spontaneous clear fluid return or upon aspiration) and spinal/epidural analgesia outcomes. The authors hypothesized that there is no difference in the...
متن کاملLabor epidural anesthetics comparing loss of resistance with air versus saline: does the choice matter?
This study examined whether air or saline, used for the loss-of-resistance (LOR) technique, resulted in a difference in pain relief or adverse events for laboring parturients. Previous studies had mixed findings regarding the onset of analgesia and subsequent pain relief. Research questions were as follows: Is there difference in analgesic onset for patients receiving air vs saline during the L...
متن کاملEpidural analgesia using loss of resistance with air versus saline: does it make a difference? Should we reevaluate our practice?
The choice of using air or saline in epidural syringes during the loss-of-resistance technique, for identifying the epidural space, has been based largely on personal preference of the anesthesia provider. A survey of practice in the United Kingdom, thought to be similar to practice in the United States, revealed that the majority of anesthesia providers use air. Case reports have appeared in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 2001
ISSN: 0003-2409
DOI: 10.1046/j.1365-2044.2001.01976-45.x