Identification Method for Single-line-to-ground Faults with Line Break Based on Phasor Measurement in Distribution Networks
نویسندگان
چکیده
The single-line-to-ground faults with line breaks (SLGFs-LBs) occur more and frequently in distribution networks can cause major safety accidents. It is difficult to distinguish the (SLGFs) resonant grounding systems ungrounding due same electrical characteristics on source side uncertain operation conditions of networks. This paper proposes a method for distinguishing SLGFs-LBs SLGFs. First, source-side load-side voltage SLGFs are analyzed, phase difference between voltages fault non-fault load selected as identification criterion. Phasor measurement units (PMUs) measuring devices. Then, effects external devices proposed discussed, errors caused by them calculated correct method. Finally, field testing simulation experiments conducted verify effectiveness robustness
منابع مشابه
Identification Faults on Transmission Line by using Phasor Measurement Unit (PMUs)
The phenomenal growth of power system network both in terms of geographical sprawl as well as technological advancements, it requires tools for dealing with the system, wide disturbances that often cause widespread catastrophic blackouts in power system networks. When a major disturbance occurs, protection and control measures play the most important role to prevent further degradation of the s...
متن کاملUnsynchronized Phasor-Based Protection Method for Single Line-to-Ground Faults in an Ungrounded Offshore Wind Farm with Fully-Rated Converters-Based Wind Turbines
This paper proposes a protection method for single line-to-ground (SLG) faults in an ungrounded offshore wind farm with fully-rated converter-based wind turbines. The proposed method uses the unsynchronized current phasors measured by unit protections installed at the connection point of the fully-rated converter (FRC)-based wind turbines (WTs). Each unit protection collects the unsynchronized ...
متن کاملSimulation Study of Single Line-to-Ground Faults on Rural Teed Distribution Lines
Teed lines are widely used in rural power networks in China. The paper theoretically analyzes the voltages and currents when a single line-to-ground fault occurs, constructs a new mathematical model for fault location on the teed lines, performs corresponding MATLAB simulations. Simulation results show that currents near the source (bus M) are almost independent of fault positions and fault res...
متن کاملA Novel Protection Method for Single Line-to-Ground Faults in Ungrounded Low-Inertia Microgrids
Abstract: This paper proposes a novel protection method for single line-to-ground (SLG) faults in ungrounded low-inertia microgrids. The proposed method includes microgrid interface protection and unit protection. The microgrid interface protection is based on the difference between the zero-sequence voltage angle and the zero-sequence current angle at the microgrid interconnection transformer ...
متن کاملPresenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units
In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of modern power systems and clean energy
سال: 2023
ISSN: ['2196-5420', '2196-5625']
DOI: https://doi.org/10.35833/mpce.2021.000288