ICRP Publication 144: Dose Coefficients for External Exposures to Environmental Sources
نویسندگان
چکیده
منابع مشابه
Fluence-to-Dose Conversion Coefficients for Muons and Pions Calculated Based on ICRP Publication 103 Using the PHITS Code
The fluence to effective-dose and organ-absorbed-dose conversion coefficients for charged pions and muons were calculated based on the instructions given in ICRP Publication 103. For the calculation, the particle motions in the ICRP/ICRU adult reference computational phantoms were simulated using the PHITS code for four idealized irradiation geometries as well as those closely representing the ...
متن کاملAbsorbed dose rate conversion coefficients for reference terrestrial biota for external photon and internal exposures.
The paper describes dosimetric models that allow the estimation of average radiation exposures to terrestrial biota due to environmental sources in the soil as well as internal uniform distributions of radionuclides. Simple three-dimensional phantoms for 13 faunal reference organisms are specified. The calculation of absorbed dose per unit source strength for these targets is based on photon an...
متن کاملImpact of the new nuclear decay data of ICRP publication 107 on inhalation dose coefficients for workers.
The impact a revision of nuclear decay data had on dose coefficients was studied using data newly published in ICRP Publication 107 (ICRP 107) and existing data from ICRP Publication 38 (ICRP 38). Committed effective dose coefficients for occupational inhalation of radionuclides were calculated using two sets of decay data with the dose and risk calculation software DCAL for 90 elements, 774 nu...
متن کاملFluence-to-dose conversion coefficients for aircrew dosimetry based on the new ICRP Recommendations
Tatsuhiko SATO, Akira ENDO, Maria ZANKL, Nina PETOUSSI-HENSS, Hiroshi YASUDA and Koji NIITA Japan Atomic Energy Agency, 2-4, Shirakata-Shirane, Tokai, Ibaraki 319-1195, Japan Helmholtz Zentrum München, German Research Center for Environmental Health (GmbH), Institute of Radiation Protection, Ingolstaedter Landstraße 1, 85764 Neuherberg, Germany National Institute of Radiological Sciences, 4-9-1...
متن کاملOrgan doses from environmental exposures calculated using the ICRP Reference Male and Reference Female voxel phantoms
In its recent recommendations the ICRP adopted two voxel models of an adult male and an adult female to be used for the forthcoming update of organ dose conversion coefficients. These voxel models are representative of an average population, i.e. they resemble the ICRP reference anatomical data with respect to their external dimensions and their organ masses and were constructed for this purpos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of the ICRP
سال: 2020
ISSN: 0146-6453,1872-969X
DOI: 10.1177/0146645320906277