ICRP Publication 133: The ICRP computational framework for internal dose assessment for reference adults: specific absorbed fractions
نویسندگان
چکیده
منابع مشابه
Computational Phantoms of the ICRP Reference Male and Reference Female
Computational models of the human body – together with radiation transport codes – have been used for the evaluation of organ dose conversion coefficients in occupational, medical and environmental radiation protection. During the last two decades, it has become common practice to use voxel models that are derived mostly from (whole body) medical image data of real persons instead of the older ...
متن کاملErratum to: Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors
1. For 79 % of the radiopharmaceuticals, the new calculations gave a lower effective dose per unit administered activity than earlier estimated.” Should be “For 63 % of the radiopharmaceuticals, the new calculations gave a lower effective dose per unit administered activity than earlier estimated.” 2. “As a mean for all radiopharmaceuticals, the effective dose was 25 % lower.” Should be“As a me...
متن کاملIDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms
BACKGROUND To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protectio...
متن کاملEffective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors
BACKGROUND Effective dose represents the potential risk to a population of stochastic effects of ionizing radiation (mainly lethal cancer). In recent years, there have been a number of revisions and updates influencing the way to estimate the effective dose. The aim of this work was to recalculate the effective dose values for the 338 different radiopharmaceuticals previously published by the I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of the ICRP
سال: 2016
ISSN: 0146-6453,1872-969X
DOI: 10.1177/0146645316661077