ICD Lead Dislodgement and Inappropriate ICD Shocks

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inappropriate ICD Shocks for Inappropriate Reasons

ICD shocks can result from a variety of etiologies; determining the proper etiology of the inappropriate shock is essential for correction of the problem. Electromagnetic interference (EMI) can mimic cardiac signals and cause inappropriate defibrillator shocks. We present two cases of inappropriate ICD shocks due to EMI and reversal of the proximal and distal DF-1 lead terminals of the ICD lead...

متن کامل

Inappropriate ICD Shocks - When Monitoring Zones Do More Than Monitor

The ventricular tachycardia (VT) monitoring zone in implantable cardioverter defibrillators (ICDs) is usually programmed to detect slow VTs. However, it is not well known whether programming this zone can affect the ICD arrhythmia redetection or confirmation criteria. We report two cases of inappropriate ICD shocks due to the programming of a slow VT monitoring zone in the same device model.

متن کامل

Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.

BACKGROUND The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate therapy (MADIT-RIT) trial showed a significant reduction in inappropriate implantable cardioverter defibrillator (ICD) therapy in patients programmed to high-rate cut-off (Arm B) or delayed ventricular tachycardia therapy (Arm C), compared with conventional programming (Arm A). There is limited data on th...

متن کامل

Trouble Shooting of ICD Therapy: Inappropriate Shock

Patients with an implantable cardioverter defibrillator (ICD) can undergo inappropriate therapies (shock or antitachycardia pacing) if electrical activity not originating in the ventricle is wrongly recognized as ventricular by the device. Inappropriate therapy leading to shocks is not innocuous; consequences include pain and its psychological sequelae, particularly anxiety, as well as inductio...

متن کامل

AV Nodal Reentrant Tachycardia Causing Inappropriate ICD Shocks In A Patient With Arrhythmogenic RV Dysplasia

We report a patient with an implantable cardioverter defibrillator (ICD) for arrhythmogenic right ventricular dysplasia (ARVD) who received inappropriate shocks for atrioventricular node reentry tachycardia (AVRNT). Patient had multiple shocks for tachycardia with EGM characteristics of very short VA interval and CL of 300 msec. An electrophysiologic (EP) study reproducibly induced typical AVNR...

متن کامل