Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
نویسندگان
چکیده
منابع مشابه
Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power ...
متن کاملA shunt active power filter control for unbalanced conditions
This paper first presents a simple control technique for active filters to compensate current harmonics and reactive power of nonlinear loads. This method is usable for both single –phase and three –phase systems. Then a new method for load balancing and reactive power compensation for unbalanced sinusoidal load currents is presented. Finally by combination of two methods an active filter contr...
متن کاملAnalysis And Simulation Of Shunt Active Power Filter Under Unbalanced And Distorted Load Conditions
Abstract— The active power filters eliminates the harmonic distortion caused by non-linear loads and improves the filtering efficiency performance when compared with the passive filters. This paper inspects about the analysis and simulation of a three phase four wire shunt active power f ilter under unbalanced and distorted load conditions. Current harmonic compensation is achieved by the imple...
متن کاملNew Hysteresis Control Method for Three Phase Shunt Active Power Filter
The quality of the current waveform generated by a current controlled, voltage source shunt active power filter depends basically on three factors: (i) The reference signal being generated; (ii) the modulation method used and (iii) the switching frequency of the PWM modulator. A new adaptive hysteresis band modulation method is proposed. In this paper, the periodical sampling constant hysteresi...
متن کاملShunt Active Power Filter with Hysteresis Current Control for three Phase Ac-Dc Converter
This paper represents the simulation of Shunt Active Power Filter(SAPF) based on p-q theory and using hysteresis current control to obtain the gating signals for three phase ac-dc converter. The proposed active power filter is employed to reduce the current Total Harmonic Distortion (THD) drawn by the non-linear load and compensate the reactive power. The PI controller is employed to reduce the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electrical and Computer Engineering
سال: 2015
ISSN: 2090-0147,2090-0155
DOI: 10.1155/2015/391040