Hypertonic versus Isotonic Salt Bridges in Ion-Selective Electrode Based Clinical Analysers

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lanthanum(III) Ion Selective Electrode Based on a New Ionophore

A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

متن کامل

Chromium (III) ion selective electrode based on di(benzylamino)glyoxime

A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

lanthanum(iii) ion selective electrode based on a new ionophore

a pvc membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(iii) ion was prepared. this electrode revealedsuch a good selectivity toward la3+ ion over a wide variety of other metal ions. some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

متن کامل

Fe (II) Ion-Selective Membrane Electrode based onTetra-Phenyl Porphyrin in PVC Matrix

Fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrixmembrane containing neutral carrier tetra phenyl porphyrin (TPP) ionophore. The addition ofsodium tetraphenylborate (NaTPB) and the plasticizer DBP has been found to substantiallyimprove the performance of the sensor. The best performance was obtained with the sensor havinga membrane of composition of TPP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Annals of Clinical Biochemistry: International Journal of Laboratory Medicine

سال: 1991

ISSN: 0004-5632,1758-1001

DOI: 10.1177/000456329102800621