Hyperpolarized 89Y-EDTMP complex as a chemical shift-based NMR sensor for pH at the physiological range
نویسندگان
چکیده
منابع مشابه
Hyperpolarized 89Y complexes as pH sensitive NMR probes.
Hyperpolarization can increase the sensitivity of NMR/MRI experiments, but the primary limitation is the T(1) decay of magnetization. Due to its long T(1), the hyperpolarized (89)Y nucleus makes an excellent candidate as an in vivo spectroscopy/imaging probe. Here we report the (89)Y chemical shift dependence upon pH for two hyperpolarized (89)Y(III) complexes and demonstrate how such complexes...
متن کاملDevelopment of 153Sm/177Lu-EDTMP as a possible therapeutic complex
Introduction:Targeted radionuclide therapy (TRT) has been demonstrated to be an effective therapeutic tool in patients with disseminated bone metastasis. TRT is generally performed with a single radionuclide. In this study we investigated the feasibility of combined TRT with a high-energy beta emitter (153Sm) and a low energy beta emitter (177Lu) in wistar...
متن کاملOptical pH Sensor Based on Quinizarin for Alkaline pH Regions
The development of an optical pH sensor based on immobilization of quinizarin (1,4-dihydroxyanthraquinone) on a triacetylcellulose membrane was described. The resulting membrane exhibited fast color change from yellow to violet, while changing the pH in alkaline region. The immobilized quinizarin showed a broader dynamic range from (pH 9.4-11.4) with respect to free form (pH 8.8-10.4). The sens...
متن کاملthe algorithm for solving the inverse numerical range problem
برد عددی ماتریس مربعی a را با w(a) نشان داده و به این صورت تعریف می کنیم w(a)={x8ax:x ?s1} ، که در آن s1 گوی واحد است. در سال 2009، راسل کاردن مساله برد عددی معکوس را به این صورت مطرح کرده است : برای نقطه z?w(a)، بردار x?s1 را به گونه ای می یابیم که z=x*ax، در این پایان نامه ، الگوریتمی برای حل مساله برد عددی معکوس ارانه می دهیم.
15 صفحه اولMultiband excitation pulses for hyperpolarized 13C dynamic chemical-shift imaging.
Hyperpolarized 13C offers high signal-to-noise ratios for imaging metabolic activity in vivo, but care must be taken when designing pulse sequences because the magnetization cannot be recovered once it has decayed. It has a short lifetime, on the order of minutes, and gets used up by each RF excitation. In this paper, we present a new dynamic chemical-shift imaging method that uses specialized ...
متن کاملذخیره در منابع من