Hygrothermal performance study of an innovative interior thermal insulation system
نویسندگان
چکیده
منابع مشابه
Experimental and Computational Analysis of Hygrothermal Performance of an Interior Thermal Insulation System
Combined experimental and computational analysis of hygrothermal performance of an interior thermal insulation system applied on a brick wall is presented in the paper. In the experimental part, the functionality of the insulation system is tested at simulated difference climate conditions using a semi-scale device. The measured temperature and relative humidity profiles are used for the calibr...
متن کاملHygric Performance of a Sandstone Wall Retrofitted with Interior Thermal Insulation
Temperature, relative humidity and overhygroscopic moisture fields in a sandstone wall provided with interior thermal insulation were calculated in order to assess the hygric performance of the retrofitted wall. Computational simulations showed that during the time period of 10 years which was subject of investigation no overhygroscopic moisture appeared in the analyzed building envelope so tha...
متن کاملThermal-insulation performance of low density polyethylene (LDPE) foams: Comparison between two radiation thermal conductivity models
The loss of energy especially in industrial and residential buildings is one of the main reasons of increased energy consumption. Improving the thermal insulation properties of materials is a fundamental method for reducing the energy losses. Polymeric foams are introduced as materials with excellent thermal insulation properties for this purpose. In the present study, a deep theoretical invest...
متن کاملa study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولInvestigation of Long-Term Thermal Insulation Performance of Vacuum Insulation Panels with Various Enveloping Methods
To practically apply vacuum insulation panels (VIPs) to buildings or home appliances, VIPs have demanded long-term lifespan with outstanding insulation performance. Service lives of VIPs enveloped with Al-foil and three-layer Al-metallized envelope are calculated. For Al-foil envelope, the service life is longer but edge conduction is too large compared with the Al-metallized envelope. To incre...