Hydrophilization of liquid surfaces by plasma treatment
نویسندگان
چکیده
منابع مشابه
Oxygen and nitrogen plasma hydrophilization and hydrophobic recovery of polymers.
PLASMA HYDROPHILIZATION AND SUBSEQUENT HYDROPHOBIC RECOVERY ARE STUDIED FOR TEN DIFFERENT POLYMERS OF MICROFABRICATION INTEREST: polydimethylsiloxane (PDMS), polymethylmethacrylate, polycarbonate, polyethylene, polypropylene, polystyrene, epoxy polymer SU-8, hybrid polymer ORMOCOMP, polycaprolactone, and polycaprolactone/D,L-lactide (P(CL/DLLA)). All polymers are treated identically with oxygen...
متن کاملRapid Hydrophilization of Model Polyurethane/Urea (PURPEG) Polymer Scaffolds Using Oxygen Plasma Treatment
Polyurethane/urea copolymers based on poly(ethylene glycol) (PURPEG) were exposed to weakly ionized, highly reactive low-pressure oxygen plasma to improve their sorption kinetics. The plasma was sustained with an inductively coupled radiofrequency generator operating at various power levels in either E-mode (up to the forward power of 300 W) or H-mode (above 500 W). The treatments that used H-m...
متن کاملVortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography
Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...
متن کاملSynthesis of Cuprous Oxide by Thermal Treatment in Liquid Paraffin
Cu2O nanoparticles were synthesized by thermal treatment in liquid paraffin without any inert gas protection using nano structures of Schiff base copper (II) complex (1) as precursor. Liquid paraffin was used as solvent and reductant. Span 80 was applied to control the morphology of cuprous oxide nanoparticles. The nano structure of the complex was characterized by X-ray diffraction measurement...
متن کاملHydrogen treatment of TiO2 nanoparticles by DC plasma
In this work structural defects were created in P25-TiO2 nanoparticles by using hydrogen DC plasma treatment in different temperatures and exposure times. X-Ray diffraction measurements show that the structure of TiO2 remains unchanged after hydrogenation. Diffuse reflectance spectroscopy measurements demonstrated band gap of TiO2 was not changed considerably by the hydrogenation. However, by a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Colloids and Surfaces A: Physicochemical and Engineering Aspects
سال: 2014