Huddle test measurement of a near Johnson noise limited geophone.
In this paper, the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved by performing the huddle test in a seismically quiet environment and by using a large number of reference sensors to remove the seismic foreground...
متن کاملJohnson Noise and Shot Noise
Two types of electrical noise fundamental to any circuit and their relation to fundamental constants are investigated. Johnson noise of a controlled-gain system is measured across different resistances and temperatures, leading to a calculation of the Boltzmann constant k = (1.48± .07)×10−23J/K and absolute zero T0 = −(270±30) ◦C. The shot noise of a variable-current system is measured, leading...
متن کاملLimited measurement dependence in multiple runs of a Bell test
The assumption of free will—the ability of an experimentalist to make random choices—is central to proving the indeterminism of quantum resources, the primary tool in quantum cryptography. Relaxing the assumption in a Bell test allows violation of the usual classical threshold by correlating the random number generators used to select measurements with the devices that perform them. In this pap...
متن کاملAir-noise reduction on geophone data using microphone records
This paper proposes using microphone recordings of air waves, recorded close to a geophone, to suppress air-wave noise on the geophone. The types of air-wave noise on the geophone may include air-coupled ground roll, air blast, ground-coupled air blast, and wind noise. Microphone recordings of air waves are related to ground measurements and geophone disturbances. We can thus attempt to use the...
متن کاملElectronic Measurement of the Boltzmann Constant with a Quantum-Voltage- Calibrated Johnson-Noise Thermometer
Currently, the CODATA value of the Boltzmann constant is dominated by a single gas-based thermometry measurement with a relative standard uncertainty of 1.8 ×10 [1]. This paper describes an electronic approach to measuring the Boltzmann constant that compares Johnson noise from a resistor at the water triple point with a pseudo-random noise generated using quantized ac-voltage synthesis. Measur...