HRTEM imaging of atoms at sub-Ångström resolution
نویسندگان
چکیده
منابع مشابه
HRTEM imaging of atoms at sub-Angström resolution.
John Cowley and his group at Arizona State University pioneered the use of transmission electron microscopy for high-resolution imaging. Images were achieved three decades ago showing the crystal unit cell content at better than 4 A resolution. This achievement enabled researchers to pinpoint the positions of heavy atom columns within the unit cell. Lighter atoms appear as resolution is improve...
متن کاملThe Hydration Structure at Yttria-Stabilized Cubic Zirconia (110)-Water Interface with Sub-Ångström Resolution
The interfacial hydration structure of yttria-stabilized cubic zirconia (110) surface in contact with water was determined with ~0.5 Å resolution by high-resolution X-ray reflectivity measurement. The terminal layer shows a reduced electron density compared to the following substrate lattice layers, which indicates there are additional defects generated by metal depletion as well as intrinsic o...
متن کاملSolid Immersion Facilitates Fluorescence Microscopy with Nanometer Resolution and Sub-Ångström Emitter Localization
Exploring the maximum spatial resolution achievable in far-field optical imaging, we show that applying solid immersion lenses (SIL) in stimulated emission depletion (STED) microscopy addresses single spins with a resolution down to 2.4 ± 0.3 nm and with a localization precision of 0.09 nm.
متن کاملCritical conditions for atomic resolution imaging of molecular crystals by aberration-corrected HRTEM.
Atomically resolved imaging of organic molecules consisting of thin crystals by aberration-corrected (AC) HRTEM was studied by experimental observations and image simulations. An atomically resolved image of the hexadecachlorophthalocyanatocopper (CuPcCl16) molecule was obtained under low-dose conditions. The conditions for imaging organic frameworks were found to be more restricted than those ...
متن کاملIn vivo diffusion tensor imaging of the human optic chiasm at sub-millimeter resolution
In this work we report findings from an in vivo diffusion tensor imaging (DTI) study of the human optic chiasm at sub-millimeter voxel resolution. Data were collected at 3 T using a diffusion-weighted radial-FSE sequence, which provides images free from typical magnetic susceptibility artifacts. The general DTI features observed in the optic chiasm region were consistent across subjects. They i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy
سال: 2005
ISSN: 2050-5701,2050-5698
DOI: 10.1093/jmicro/dfi036