HORIZONTAL LOADING EXPERIMENT ON BREAKWATER REINFORCED BY STEEL PIPE PILES
نویسندگان
چکیده
منابع مشابه
Prediction of End Bearing Capacity for Pre-Bored Steel Pipe Piles Using Instrumented Spt Rods
The standard penetration test (SPT) has been widely used because of its usability, economy, and many correlations with soil properties among other factors. In SPT, hammer energy is an important factor to evaluate and calibrate N values. To measure hammer energy, an instrumented SPT rod was developed considering that stress waves transferring on rods during SPT driving are the same as stress wav...
متن کاملNumerical and Experimental Investigations on the Behavior of Steel-reinforced Concrete Columns Subjected to Eccentric Loading
Steel-reinforced concrete (SRC) columns, which are classified as composite columns, became the most widely used in recent years; because of their extensive advantages over the reinforced concrete and the steel columns. In this paper, the ductility index and its influential factors were explored to investigate the behavior of SRC columns. A straightforward approach was then proposed by establish...
متن کاملStudy on Bearing Capacity of Prestressed Pipe Pile Foundation Under Horizontal Load
Received: June 12, 2017 Revised: October 24, 2017 Accepted: November 03, 2017 Abstract: Background and Objective: Prestressed high strength concrete pipe pile (PHC) shows brittle fracture when subjected to more than its own bearing capacity. Therefore, the non-prestressed steel bar is added to the PHC pipe pile, that is, the mixed reinforced pipe pile (PRC). The mechanical behavior of PRC group...
متن کاملSome Studies on Steel Fiber Reinforced Concrete
Fibres are generally used as resistance of cracking and strengthening of concrete. In this project, I am going to carry out test on steel fibre reinforced concrete to check the influence of fibres on flexural strength of concrete. According to various research papers, it has been found that steel fibres give the maximum strength in comparison to glass and polypropylene fibres. Hence, in this pr...
متن کاملFlow Field Analysis of Submerged Horizontal Plate Type Breakwater
A submerged horizontal plate type breakwater is pointed out as an efficient wave protection device for cage culture in marine fishery. In order to reveal the wave elimination principle of this type breakwater, boundary element method is utilized to investigate this problem. The flow field and the trajectory of water particles are studied carefully. The flow field analysis shows that: the intera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Japan Society of Civil Engineers, Ser. B3 (Ocean Engineering)
سال: 2015
ISSN: 2185-4688
DOI: 10.2208/jscejoe.71.i_617